Super Heated Water Spray Steriliser

Steam & Air Mixture Sterilizer

Rs 10 Lakh / Unit

Steam & Air Mixture Sterilizer
  • Application Industrial
  • Chamber Volume 15 - 20 L
  • Shape Horizontal
  • Mount Type Floor Mounted Autoclave
  • Brand Neelam Industries
  • Insulation Wall Single Wall
  • Material Aluminium
  • Automation Grade Fully Automatic
  • Temperature Range 121 deg C to 125 deg C
  • Pressure Range (psi) 28 psi
  • Approval Certificate ISO 9001 2008
  • Warranty 1 Year
  • Type of Sterilizer Steam Sterilizer
Steam Sterilizer manufactured by Neelam industries are used for treatments of infusion/ high-volume parenteral solutions, packed in sealed containers (e.g.PVC,PE,PP.bottles, glass bottles or plastic bags or pouch, Filled PP, PE , & PVC syringes & Ampoules) without any kind of blushing phenomena.

FEATURES Single or double door with Sliding or Hinged door options
A ventilator is a rectangular or cylindrical pressure vessel with heat exchangers along the side curvature supported by inverted u shaped chamber construction at the bottom of the ventilator.
A centrally places impeller along with the heat exchanger coils & the chamber baffle at the bottom comprise the recirculation system. This ensures high flow velocity of steam air mixture during the heating period and the desired temperature attainment and uniformity for sterilization purpose is thereby attained.
Recirculation of the steam air mixture also causes necessary pressure balancing thereby preventing any deformation of the flexible load.
Design for installation on the floor ( for loading with in-chamber & transfer trolley) or pit mounted (for loading at floor level with in/out trolleys or automatic loading/unloading units)
Single or double door with Sliding or Hinged door options to suit client specific requirements.
Cylindrical single-wall chamber in highly finish AISI 316L stainless steel.
Chamber pipings and fittings in AISI 316L stainless steel, Tri-clover clamp connection.
Pressure Monitoring inside the chamber by pressure transmitter.
Automatic Printing facility for control in case of heat labile materials.
The touch-screen for visual process control and connections for measuring signals and printers.
Remote support connection
Online Printing and recording confirming to 21 CFR PART 11.
0.2 bacteria retentive, sterile air filter for vacuum break. [Optional SIP facility can be provided]
Contamination Seal to prevent cross-flow of air between the clean and un-clean area.
Validation ports for insertion of temperature sensors for thermometric testing.
In compliance with  
cGMP, FDA for LVP and SVP, GAMP,

Main applications 
  • Large volume infusion/parenteral solutions in sealed glass, PP, PE, etc. bottles
  • Large volume infusion/parenteral solutions in sealed PVC, PP, PE, etc. bags without blushing phenomena or any color changing
  • Blood bags (with operation at temperatures below 75C)
  • Filled syringes and ampoules
  • Blister packed products
  • Contact lenses
...more

Super Heated Water Spray Sterilizer

Rs 10 Lakh / Unit

Super Heated Water Spray Sterilizer
  • Automation Grade Semi Automatic
  • Type of Sterilizer Steam Sterilizer
  • Chamber Volume (Litre) 10-15 Litre
  • Material Stainless Steel
  • Insulation Wall Single Wall
Super Heated Water Spray Sterilizer manufactured by Neelam industries are designed for cGMP to perform terminal sterilisation of large volume infusion / Parenteral solution in Non-deformable container (e.g. glass bottles) as well as in containers deformable by differential pressure under Heat exposure (e.g. plastic bottles, plastic bags) proven to withstand sterilization condition by hot water spray.

FEATURES :
  • Design for installation on the floor ( for loading with in-chamber & transfer trolley) or pit mounted (for loading at floor level with in/out trolleys or automatic loading/unloading units)
  • Single or double door with Sliding or Hinged door options to suit client specific requirements.
  • Cylindrical single-wall chamber in highly finish AISI 316L stainless steel.
  • Chamber pipings and fittings in AISI 316L stainless steel, Tri-clover clamp connection.
  • Water spray distribution headers fitted with nozzle suitably located to assure water uniform distribution on the product with consequent excellent temperature uniformity throughout the entire load.
  • High efficiency plate type heat exchanger, in AISI 316L S.S., for recirculation of heating / cooling water.
  • Pressure Monitoring inside the chamber by pressure transmitter.
  • Water level monitoring inside the chamber by sight level assembly and capacitive level sensors.
  • Automatic Printing facility for control in case of heat labile materials.
  • The touch-screen for visual process control and connections for measuring signals and printers.
  • Remote support connection
  • Online Printing and recording confirming to 21 CFR PART 11.
  • 0.2 bacteria retentive, sterile air filter for vacuum break. [Optional SIP facility can be provided]
  • Contamination Seal to prevent cross-flow of air between the clean and un-clean area.
  • Validation ports for insertion of temperature sensors for thermometric testing.

In compliance with :
cGMP, GAMP, ISO 9001 : 2008

Main applications :
  • Large volume infusion/parenteral solutions in sealed glass, PP, PE, etc. bottles  quick cycle
  • Large volume infusion/parenteral solutions in sealed PVC, PP, PE, etc. bags  quick cycle
...more

Sterilizers

Rs 10 Lakh / Unit

Sterilizers
  • Insulation Wall Single Wall
  • Automation Grade Fully Automatic
  • Type of Sterilizer Steam Sterilizer
  • Chamber Volume (Litre) 10-15 Litre
  • Material Stainless Steel
Steam Sterilizer are the most versatile and flexible designed manufactured by Neelam industries to meet the widest requirements of the Pharmaceutical Industry.

Features :
  • The equipment is low on operating cost and fast with autoclaving cycle and possess dimple steam jacket for uniform heat distribution.
  • Available in single as well as double door with sliding or hinged door option.
  • Available with automatic printing facility to control heat labile materials.
  • Touch screen is present to measure connection signals, printers and process control visuals.
  • The connections are supported by remote control.
  • The printing and recording is in confirmation with 21 CFR PART 11.
  • Sterile air filter is available for vaccum break.
  • An optional SIP filter is also provided as per the requirements.
  • To prevent the cross-flow of air between the clean and unclean area, a contamination seal is provided.
  • To insert the temperature sensors, which support thermometric testing, validation ports are provided.
Programs :
  • HPHV Cycle
  • Fast Exhaust Cycle
  • Slow Exhaust
  • Chamber Leack Test Cycle
  • Bowie Dick Test Cycle
  • AOP Cycle ( FOR Liquid Solution Sealed in Ampoule & Vial )

In Compliance With :
  • cGMP, GAMP, ISO 9001 : 2008

Main Applications :
  • Empty glassware (e.g. vials, ampoules, bottles)
  • Stoppers
  • Inox equipment and instruments
  • Inox machine parts
  • Empty containers
  • Filters and accessories
  • Rubber materials
  • Textiles
...more

Steam Sterilizer

Rs 10 Lakh / Unit

Steam Sterilizer
  • Size 450 mm X 450 mm X 900 mm
  • Material Stainless steel
  • Power source Electric
  • Capacity 200 L
  • Voltage 380 V
Steam Sterilizer are the most versatile and flexible designed manufactured by Neelam industries to meet the widest requirements of the Pharmaceutical Industry.

Features :
  • The equipment is low on operating cost and fast with autoclaving cycle and possess dimple steam jacket for uniform heat distribution.
  • Available in single as well as double door with sliding or hinged door option.
  • Available with automatic printing facility to control heat labile materials.
  • Touch screen is present to measure connection signals, printers and process control visuals.
  • The connections are supported by remote control.
  • The printing and recording is in confirmation with 21 CFR PART 11.
  • Sterile air filter is available for vaccum break.
  • An optional SIP filter is also provided as per the requirements.
  • To prevent the cross-flow of air between the clean and unclean area, a contamination seal is provided.
  • To insert the temperature sensors, which support thermometric testing, validation ports are provided.
Programs :
  • HPHV Cycle
  • Fast Exhaust Cycle
  • Slow Exhaust
  • Chamber Leack Test Cycle
  • Bowie Dick Test Cycle
  • AOP Cycle ( FOR Liquid Solution Sealed in Ampoule & Vial )

In Compliance With :
  • cGMP, GAMP, ISO 9001 : 2008

Main Applications :
  • Empty glassware (e.g. vials, ampoules, bottles)
  • Stoppers
  • Inox equipment and instruments
  • Inox machine parts
  • Empty containers
  • Filters and accessories
  • Rubber materials
  • Textiles
...more
x

Send us a Quick Message

country flag
x

Provide Us More Details

Purpose of Requirement:

Reselling End Use Raw Material

We recommend you to enter details of your requirement to get quick quotations.
x
< Back
company logo

Neelam Industries